IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristics (HCPL-2300 Option 060 only)DescriptionSymbolCharacteristicUnits Installation classification per DIN VDE 0110/39, Table 1 for rated mains voltage ≤300 V I-IV rms for rated mains voltage ≤600 V I-IV rms Climatic Classification 55/85/21 Pollution Degree (DIN VDE 0110/39) 2 Maximum Working Insulation Voltage V 630 V IORM peak Input to Output Test Voltage, Method b* V 1181 V PR peak V x 1.875 = V , 100% Production Test with t = 1 sec, IORM PR m Partial Discharge < 5 pC Input to Output Test Voltage, Method a* V 1008 V PR peak V x 1.6 = V , Type and sample test, t = 10 sec, IORM PR m Partial Discharge < 5 pC Highest Allowable Overvoltage* V 8000 V IOTM peak (Transient Overvoltage, t = 60 sec) ini Safety Limiting Values (Maximum values allowed in the event of a failure, also see Figure 11, Thermal Derating curve.) Case Temperature T 175 °C S Input Current I 230 mA S,INPUT Output Power P 600 mW S,OUTPUT Insulation Resistance at TS, VIO = 500 V RS ≥109 Ω *Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-5, for a detailed description. Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application. Absolute Maximum Ratings (No Derating Required up to 55°C) DescriptionMin.Typ.Max.Units Storage Temperature -55°C +125°C TS Operating Temperature -40°C +85°C TA Lead Solder Temperature 260°C for 10 s max (1.6 mm below seating plane) Average Forward Input Current 5 mA [2] - IF Reverse Input Voltage 3.0 V VR Supply Voltage 0 V 7.0 V VCC Pull-Up Resistor Voltage -0.5 V VCC VRL Output Collector Current -25 mA 25 mA IO Input Power Dissipation 10 mW PI Output Collector Power Dissipation 40 mW PO Output Collector Voltage -0.5 V 18 V VO Infrared and Vapor Phase Reflow Temperature (Option #300) see Fig. 1, Thermal Profile 6