Datasheet Texas Instruments 5962-9326101M2A — 数据表

制造商Texas Instruments
系列UC1854
零件号5962-9326101M2A
Datasheet Texas Instruments 5962-9326101M2A

数据表

UCx854 High-Power Factor Preregulator datasheet
PDF, 949 Kb, 修订版: A, 档案已发布: Dec 16, 2016
从文件中提取

价格

状态

Lifecycle StatusObsolete (Manufacturer has discontinued the production of the device)
Manufacture's Sample AvailabilityNo

打包

Pin20
Package TypeL

参数化

Control MethodCCM
Duty Cycle(Max)(%)95
Operating Temperature Range(C)-55 to 125
Package GroupCDIP
Package Size: mm2:W x L (PKG)See datasheet (CDIP)
RatingMilitary
Special FeaturesAverage Current Mode
Enable
UVLO Thresholds On/Off(V)16/10

生态计划

RoHSNot Compliant
Pb FreeNo

应用须知

  • U-134 UC3854 Controlled Power Factor Correction Circuit Design
    PDF, 346 Kb, 档案已发布: Sep 5, 1999
    The UC1854 provides active power factor correction for power systems that otherwise would draw non-sinusoidal current from sinusoidal power lines. This device implements all the control functions necessary to build a power supply capable of optimally using available power-line current while minimizing line-current distortion. This application note describes the concepts and design of a boost prere
  • AC Requirements for Power Factor Correction Circuits
    PDF, 29 Kb, 档案已发布: Mar 28, 2002
    This technical brief identifies the recommended range of IAC for each of the devices within the UCC3854 family of PFC controllers.
  • DN-39E Optimizing Performance in UC3854 Power Factor Correction Applications
    PDF, 277 Kb, 档案已发布: Sep 5, 1999
    The performance of the UC3854 Power-Factor Correction IC in the 250W application example has been evaluated using a precision PFC/THD instrument. The result was a power factor of 0.999 and Total Harmonic Distortion (THD) of 3.81%, measured to the 50th line frequency harmonic at nominal line and full load. Users should get similar results at these conditions. as well as over most line and load rang
  • Accurate PWM Duty Cycle Clamp
    PDF, 58 Kb, 档案已发布: Jan 25, 2002
    Power supply applications using current sense transformers require a duty cycle clamp on the pulse width modulator (PWM) to ensure transformer reset. Not all PWMs come with a duty cycle clamp presenting a problem for the power supply designer. This application note shows how to implement a duty cycle clamp by using a simple delay circuit.
  • DN-41 Extend Current Transformer Range
    PDF, 37 Kb, 档案已发布: Sep 5, 1999
    The problems with self reset of current transformers for unipolar pulse applications can be overcome with simple forced-reset techniques derived from magnetic amplifiers. Duty factors above 90% are achievable with these techniques. This design note describes a circuit configured for forced reset and a configuration that generates a negative voltage from the current transformer.

模型线

系列: UC1854 (6)

制造商分类

  • Semiconductors > Space & High Reliability > Power Management Products > Offline and Isolated DC/DC Controller and Converter

其他名称:

59629326101M2A, 5962 9326101M2A