Datasheet Texas Instruments UCC28517DWR — 数据表

制造商Texas Instruments
系列UCC28517
零件号UCC28517DWR
Datasheet Texas Instruments UCC28517DWR

先进的PFC / PWM组合控制器20-SOIC -40至105

数据表

Advanced PFC/PWM Combination Controllers datasheet
PDF, 1.5 Mb, 修订版: C, 档案已发布: Sep 14, 2005
从文件中提取

价格

状态

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityYes

打包

Pin20
Package TypeDW
Industry STD TermSOIC
JEDEC CodeR-PDSO-G
Package QTY2000
CarrierLARGE T&R
Device MarkingUCC28517DW
Width (mm)7.5
Length (mm)12.8
Thickness (mm)2.35
Pitch (mm)1.27
Max Height (mm)2.65
Mechanical Data下载

参数化

Control MethodCCM
Device TypePFC+PWM
Operating Supply Current4 mA
Operating Supply(Max)18 V
Operating Temperature Range-40 to 105 C
Package GroupSOIC
Package Size: mm2:W x L20SOIC: 132 mm2: 10.3 x 12.8(SOIC) PKG
Peak Output Sink Current Gate Drive3 A
Peak Output Source Current Gate Drive-2 A
Practical Operating Frequency(Max)0.5 MHz
RatingCatalog
Special FeaturesAverage Current Mode,Enable,OVP
Startup Current0.1 mA
UVLO Thresholds On/Off10.2/9.7 V

生态计划

RoHSCompliant

设计套件和评估模块

  • Evaluation Modules & Boards: UCC28514EVM
    UCC28514 Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)

应用须知

  • UCC28517 100-W PFC power converter with 12-V, 8-W bias supply, Part 2
    PDF, 224 Kb, 档案已发布: Feb 28, 2005
    To conclude the review of the UCC28517 PFC supply, this article covers the design of the second 12-V, 8-W power stage to be used as an auxiliary bias supply.
  • UCC28517 100-W PFC power converter with 12-V, 8-W bias supply, Part 1
    PDF, 202 Kb, 档案已发布: Feb 28, 2005
    Power factor corrected (PFC) preregulators are generally used in ac/dc converters operating above 75 W or to meet line harmonic requirements. This article reviews the design of a 100-W ac/dc power stage with PFC.
  • Bootstrap Circuit for Green Mode Applications
    PDF, 111 Kb, 档案已发布: Jan 27, 2006
  • A New Synchronization Circuit for Power Converters (Rev. A)
    PDF, 209 Kb, 修订版: A, 档案已发布: Apr 21, 2010
    The synchronization of multiple PWM and PFC controllers is desirable for many reasons. The most common reason is that it keeps all the noise at one particular frequency and makes it easier to filter. The circuit described changes the slope of the ramp to lock the converter’s switching frequency to an applied signal by a phase locked loop turning it into a voltage controlled oscillator. Furthermore
  • Startup Current transient of the Leading Edge Triggered PFC Controllers
    PDF, 43 Kb, 档案已发布: Jun 30, 2004
  • Avoiding Audible Noise at Light Loads When Using Leading Edge Triggered PFC Con (Rev. C)
    PDF, 57 Kb, 修订版: C, 档案已发布: Apr 13, 2011
    This application note applies to the TI average current mode, leading edge modulation PFC controllers. See Applicable Device Table for part numbers.

模型线

系列: UCC28517 (2)

制造商分类