CAP400DGAbsolute Maximum Ratings(4) DRAIN Pin Voltage(1) ... 900 V Notes: DRAIN Peak Current(2) ...10.2 mA 1. Voltage of D1 pin relative to D2 pin in either polarity. Storage Temperature ..-65 °C to 150 °C 2. The peak DRAIN current is al owed while the DRAIN voltage is Lead Temperature(3) ..260 °C simultaneously less than 400 V. Operating Ambient Temperature ... -40 °C to 125 °C 3. 1/16 in. from case for 5 seconds. Maximum Junction Temperature ... -40 °C to 125 °C 4. The Absolute Maximum Ratings specified may be applied one at a time without causing permanent damage to the product. Exposure to Absolute Maximum Rating conditions for extended periods of time may affect product reliability. Thermal Resistance Thermal Resistance: D Package(1): Notes: (q ) ...160 °C/W (Single layer JEDEC PCB) 1. Reference thermal resistance test conditions: JEDEC JESD51-3, JA (q ) ..40 °C/W (Bottom) SEMI Test Method #G43-87, and MIL-STD-883 Method 10121.1. JC (q ) ... 75 °C/W (Top) JC ConditionsParameterSymbol T = -40 to 125 °C A MinTypMaxUnits (Unless Otherwise Specified) Control FunctionsAC RemovalDetection Time t Line Cycle Frequency 47 - 63 Hz 20 22 36 ms DETECT Drain SaturationCurrentA,B I CAP400DG 5 mA DSAT Supply Current I T = 25 °C 2.5 3.4 mA SUPPLY A Power Consumption Pin T = 25 °C 600 mW A NOTES: A. Saturation current specification ensures a RC discharge characteristic at all voltages up to 265 VAC with the external resistor values specified in Table 1. B. Specifications are guaranteed by characterization and design. 4PRELIMINARY Rev. A 06/26 www.power.com