Datasheet DK (Panasonic) - 9

制造商Panasonic
描述1 Form A 10 A, 1 Form A 1 Form B/2 Form A 8 A, Small polarized power relays
页数 / 页15 / 9 — Power Relays ( Over 2 A ) DK RELAYS.  . ●. …
文件格式/大小PDF / 474 Kb
文件语言英语

Power Relays ( Over 2 A ) DK RELAYS.  . ●. Minimum switching load is a guide to the lower .  . ●

Power Relays ( Over 2 A ) DK RELAYS   ● Minimum switching load is a guide to the lower    ●

该数据表的模型线

文件文字版本

Power Relays ( Over 2 A ) DK RELAYS   ● Minimum switching load is a guide to the lower    ● Specification values of operate ( set ) voltage and  current limit of switching under the micro-load.  release ( reset ) voltage were measured with a relay  This parameter is changed by the condition, such as  oriented terminals down.  switching times, environment condition, and expected  Set the relay facing the terminals downward when  reliability.  operate ( set ) voltage and release ( reset ) voltage are  Therefore, Panasonic Industry Co., Ltd. cannot assure  measured. the reliability.    ● Latching type is recommended when the relay is  When the relay is used lower than minimum switching  continuously energized. load, reliability is attrition.    ●  ( Latching type ) Please use the relay over minimum switching load. Regarding the set/reset pulse time of the latching type    ● If the relay is dropped, it should not be used again. relay, it is recommended to apply rated voltage for    ● When a source of silicone gas ( silicone rubber, silicone  minimum 50 ms pulse across the coil to secure the sure  oil, silicone coating materials and silicone filling  operation considering the ambient temperature and  materials etc. ) is used around the relay, the silicone  condition change through service life. gas ( low molecular weight siloxane etc. ) may be    ● ( Latching type ) produced.  The relays are shipped from the factory in the reset state. The produced silicone gas may penetrate the plastic  A shock to the relay during shipping or installation may  case and enter the inside of the relay. When the relay  change it to the set state. is kept and used in this condition, silicone compound  Therefore, it is recommended to use the relay in a circuit  may adhere to the relay contacts.  which initializes the relay to the required state ( set or  The silicon compound may be changed to the insulator  reset ) whenever the power is turned on. which may cause the contact failure. Do not use any    ●  ( 1 Form A 1 Form B type )  source of silicone gas around the relay. Please note that when this relay operates or resets, both    ● Do not use the relay in areas where flammable or  the normally open ( N.O. ) and normally closed ( N.C. )   explosive gases from gasoline and thinner, etc., may  contacts may turn ON simultaneously, which could  be present. adversely affect the circuit.   ● Please check the insulation distance between each    ● The product specifications may be changed based  terminal and ground. on product improvements and another reasons    ● Please absolutely avoid the ultrasonic and high  ( specification changes, Including production  frequency vibration to the relay that adversely affects  discontinuation ). its performance. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industry.panasonic.com Panasonic Industry Co., Ltd. 2025 ASCTB177E 202507 ー 8 ー