9 | 60 Bosch Sensortec | BME280 Data sheet 1.2 Humidity parameter specification Table 2: Humidity parameter specification Parameter Operating range 1 Supply current Symbol Condition Min Typ Max Unit RH For temperatures < 0 °C and > 60 °C see Figure 1 -40 25 85 °C 100 %RH 2.8 µA 0 IDD,H 1 Hz forced mode, humidity and temperature 1.8 Absolute accuracy tolerance AH 20…80 %RH, ±3 %RH Hysteresis 2 HH 109010 %RH, 25 °C ±1 %RH Nonlinearity 3 NLH 1090 %RH, 25 °C 1 %RH Response time to complete 63% of step 4 𝜏𝜏63% 900 or 090 %RH, 25°C 1 s 0.008 %RH 25 °C, including hysteresis Resolution RH Noise in humidity (RMS) NH Highest oversampling, see chapter 3.6 0.02 %RH ∆Hstab 10…90 %RH, 25 °C 0.5 %RH/ year Long term stability When exceeding the operating range (e.g. for soldering), humidity sensing performance is temporarily degraded and reconditioning is recommended as described in section 7.8. Operating range only for non-condensing environment. 2 For hysteresis measurement the sequence 103050709070503010 %RH is used. The hysteresis is defined as the difference between measurements of the humidity up / down branch and the averaged curve of both branches 3 Non-linear contributions to the sensor data are corrected during the calculation of the relative humidity by the compensation formulas described in section 4.2.3. 4 The air-flow in direction to the vent-hole of the device has to be dimensioned in a way that a sufficient air exchange inside to outside will be possible. To observe effects on the response time-scale of the device an air-flow velocity of approx. 1 m/s is needed. 1 Modifications reserved | Data subject to change without notice Document number: BST-BME280-DS001-23 Revision_1.23_012022