9 | 60 Bosch Sensortec | BME280 Data sheet 1.2 Humidity parameter specification

9 | 60 Bosch Sensortec | BME280 Data sheet 1.2 Humidity parameter specification

该数据表的模型线

文件文字版本

9 | 60 Bosch Sensortec | BME280 Data sheet 1.2 Humidity parameter specification
Table 2: Humidity parameter specification Parameter
Operating range 1 Supply current Symbol Condition Min Typ Max Unit RH For temperatures
< 0 °C and > 60 °C
see Figure 1 -40 25 85 °C 100 %RH 2.8 µA 0 IDD,H 1 Hz forced mode,
humidity and
temperature 1.8 Absolute accuracy
tolerance AH 20…80 %RH, ±3 %RH Hysteresis 2 HH 109010 %RH,
25 °C ±1 %RH Nonlinearity 3 NLH 1090 %RH, 25 °C 1 %RH Response time to
complete 63% of step 4 𝜏𝜏63% 900 or 090 %RH,
25°C 1 s 0.008 %RH 25 °C, including
hysteresis Resolution RH Noise in humidity (RMS) NH Highest oversampling,
see chapter 3.6 0.02 %RH ∆Hstab 10…90 %RH, 25 °C 0.5 %RH/
year Long term stability When exceeding the operating range (e.g. for soldering), humidity sensing performance is temporarily degraded and
reconditioning is recommended as described in section 7.8. Operating range only for non-condensing environment.
2
For hysteresis measurement the sequence 103050709070503010 %RH is used. The hysteresis is defined as
the difference between measurements of the humidity up / down branch and the averaged curve of both branches
3
Non-linear contributions to the sensor data are corrected during the calculation of the relative humidity by the compensation
formulas described in section 4.2.3.
4
The air-flow in direction to the vent-hole of the device has to be dimensioned in a way that a sufficient air exchange inside to
outside will be possible. To observe effects on the response time-scale of the device an air-flow velocity of approx. 1 m/s is
needed.
1 Modifications reserved | Data subject to change without notice Document number: BST-BME280-DS001-23 Revision_1.23_012022