Datasheet LT1610 (Analog Devices) - 3

制造商Analog Devices
描述1.7MHz, Single Cell Micropower DC/DC Converter
页数 / 页16 / 3 — ELECTRICAL CH. ARA TERISTICS The. denotes specifications which apply over …
文件格式/大小PDF / 224 Kb
文件语言英语

ELECTRICAL CH. ARA TERISTICS The. denotes specifications which apply over the specified temperature

ELECTRICAL CH ARA TERISTICS The denotes specifications which apply over the specified temperature

该数据表的模型线

文件文字版本

LT1610
ELECTRICAL CH C ARA TERISTICS The

denotes specifications which apply over the specified temperature range, otherwise specifications are at TA = 25
°
C. Commercial grade 0
°
C to 70
°
C, VIN = 1.5V, VSHDN = VIN, unless otherwise noted. (Note 2) PARAMETER CONDITIONS MIN TYP MAX UNITS
Switch Current Limit (Note 3) 450 600 900 mA Switch VCESAT ISW = 300mA 300 350 mV ● 400 mV Switch Leakage Current VSW = 5V 0.01 1 µA SHDN Input Voltage High 1 V SHDN Input Voltage Low 0.3 V SHDN Pin Bias Current VSHDN = 3V 10 µA VSHDN = 0V 0.01 0.1 µA
The

denotes specifications which apply over the specified temperature range, otherwise specifications are at TA = 25
°
C. Industrial grade – 40
°
C to 85
°
C, VIN = 1.5V, VSHDN = VIN, unless otherwise noted. PARAMETER CONDITIONS MIN TYP MAX UNITS
Minimum Operating Voltage TA = 85°C 0.9 1 V TA = – 40°C 1.25 V Maximum Operating Voltage 8 V Feedback Voltage ● 1.20 1.23 1.26 V Quiescent Current 30 60 µA Quiescent Current in Shutdown VSHDN = 0V, VIN = 2V 0.01 0.5 µA VSHDN = 0V, VIN = 5V 0.01 1.0 µA FB Pin Bias Current ● 27 80 nA Reference Line Regulation 2V ≤ VIN ≤ 8V (– 40°C) 0.03 0.15 %/V 2V ≤ VIN ≤ 8V (85°C) 0.2 %/V Error Amp Transconductance ∆I = 2µA 25 µmhos Error Amp Voltage Gain 100 V/V Switching Frequency (Note 4) ● 1.4 1.7 2 MHz Maximum Duty Cycle (Note 4) 77 80 95 % ● 75 95 % Switch Current Limit 450 600 900 mA Switch VCESAT ISW = 300mA 300 350 mV ● 400 mV Switch Leakage Current VSW = 5V 0.01 1 µA SHDN Input Voltage High 1 V SHDN Input Voltage Low 0.3 V SHDN Pin Bias Current VSHDN = 3V 10 µA VSHDN = 0V 0.01 0.1 µA
Note 1:
Absolute Maximum Ratings are those values beyond which the life
Note 3:
Current limit guaranteed by design and/or correlation to static test. of a device may be impaired. Current limit is affected by duty cycle due to ramp generator. See Block
Note 2:
The LT1610C is guaranteed to meet specified performance from Diagram. 0°C to 70°C and is designed, characterized and expected to meet these
Note 4:
Not 100% tested at 85°C. extended temperature limits, but is not tested at – 40°C and 85°C. The LT1610I is guaranteed to meet the extended temperature limits. 3