Datasheet Texas Instruments TPS26602PWPT — 数据表

制造商Texas Instruments
系列TPS2660
零件号TPS26602PWPT

具有集成反向输入极性保护的60V 2A工业电子保险丝16-HTSSOP -40至125

数据表

TPS2660x 60-V, 2-A Industrial eFuse With Integrated Reverse Input Polarity Protection datasheet
PDF, 4.0 Mb, 修订版: D, 档案已发布: Apr 7, 2017
从文件中提取

价格

状态

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

打包

Pin16
Package TypePWP
Industry STD TermHTSSOP
JEDEC CodeR-PDSO-G
Package QTY250
CarrierSMALL T&R
Device Marking26602
Width (mm)4.4
Length (mm)5
Thickness (mm)1
Pitch (mm).65
Max Height (mm)1.2
Mechanical Data下载

参数化

Channel(s) Controlled1
Current Limit Accuracy+/-5% @1A
Current Limit Function EnabledAlways
Current Limit TypeAdjustable
Current Limit(Max)2.23 A
Current Limit(Min)0.1 A
FET ProtectionSOA,Thermal
Fault ResponseAuto Retry,Latch Off
Imax2 A
Number of Channels1
Operating Temperature Range-40 to 125 C
Overcurrent ResponseCurrent Limiting, Circuit Breaker with Auto Retry
Overvoltage ResponseClamp
Package GroupHTSSOP
Package Size: mm2:W x L16HTSSOP: 22 mm2: 4.4 x 5(HTSSOP) PKG
Rise Time(Typ)Adjustable us
Ron(Typ)150 mOhm
Special FeaturesAdjustable Rise Time,Analog IMON Output,Current Sense/Monitor,Fault Reporting,Low Iq Shutdown,No RSENSE Required,No Reverse Current When Off,Output Clamp,Over Current Reporting,Over Temp Reporting,Overvoltage Protection,Power MUXing,Reverse Current Blocking,Reverse Current Protection,Thermal Shutdown,Undervoltage Protection,dV/dT
UL RecognitionYes
Vabsmax_cont60 V
Vin(Max)55 V
Vin(Min)4.2 V

生态计划

RoHSCompliant

设计套件和评估模块

  • Evaluation Modules & Boards: TPS26600-02EVM
    TPS2660 Integrated 60V 2.23A Industrial eFuse Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)

应用须知

  • The TPS2660 Simplifies Surge and Power-Fail Protection Circuits in PLC System
    PDF, 9.9 Mb, 档案已发布: Oct 25, 2016
    The Programmable Logic Controller (PLC) system is usually connected to an external DC power supply to provide power to the controller unit, backplane and I/O modules. The input protection circuits are required to protect the PLC from various faults that may occur either on the field or the PLC side. Traditionally, discrete or semi-integrated circuits have been the solution and require a lot of ext
  • Power Multiplexing Using Load Switches and eFuses (Rev. A)
    PDF, 1.1 Mb, 修订版: A, 档案已发布: Jun 20, 2017

模型线

制造商分类

  • Semiconductors > Power Management > Protection, Monitoring and Hot Swap > eFuses (Integrated FET)